Limited Software Version History
2025.1.0
Released January 30, 2025
Download 20|20 limited software version 2025.1.0
Download 20|20 limited boot software version 2025.1.0
New Features
- Added Passmaster
- Added Pneumatic Down Force
- Added Rate and Swath control for Seeding
- Added fan speed sensor for granular carts
- Added per row Row unit and measurement configuration
- Added custom CCM mapping
- Added configuration of BUS module location and Ethernet module serial number based on detection
Improved Setup Menu
- The Setup menu is now structured more intuitively.
- Harnessing is now under Equipment -> Implement -> Modules.
- The new navigation menu allows you to see exactly where you are in the 20|20 and quickly navigate to where you want to go.
- Tired of manually adding modules? Now detected modules and their predicted locations are filled in for you in a streamlined setup process.
- Find the settings you care about quicker with surfaced settings and a more intuitive layout.
- Easily find out where your diagnostic problems are happening with the new surfaced information on the diagnose dashboard.
Required Action When Upgrading from 2025.0.0 or 2024.0.1 or earlier.
-
New setup required for all users:
- Harnessing must now be set up explicitly in Systems (under Implement → Harnessing).
- Row Unit Type must now be specified in Equipment.
- Home Screen Reconfigured
-
Required setup if upgrading with specific hardware:
- Add Good Ride Sensors for SRMs with accelerometers
- Smart Connector will need to be set up again.
- EM FlowSense Sensing modules will need to be assigned. (All existing EM FlowSense modules will map to EM FlowSense Control)
- Rate Control Modules will need to be reconfigured. They will map to vApply flow/pressure control modules upon migration.
- All sensors should be zeroed in Calibrations (Down Force, FurrowForce, EM FlowSense).
- SmartDepth range and offset Calibrations are also required.
- If using implement-mounted GPS, you will need to add it to the Planter in Equipment, via the Add Hardware button and enter the GPS offsets for the implement mounted GPS.
- FCIM must be added and configured for Momentum planters
Required Action When Upgrading from 2024.1.x
-
New Ethernet Setup
- Ethernet Modules must be added and configured in Modules (under Equipment -> Vehicle).
Setup Videos
The Product Support team has put together a helpful series of videos on setting up 2023.1 software. Be sure to check them out if you'd like to see someone walk through the setup process.